text.skipToContent text.skipToNavigation

E-PSM(P) Non-invasive Blood Pressure (NIBP) Pump

M1221540
M1011858
Patient Monitoring
GE HealthCare
Outright
Add to Wish List
Login To Shop
Login To Shop
Please select date
Second Opinion Approval Needed

Enter your approval number and submit to add item(s) to cart.

Approval Number

Please enter approval number

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.

Second Opinion Approval Needed

Select your approver's name and submit to add item(s) to your cart

Approver Name

Please Select Approver Name

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.


Features

  • Easy to Remove
  • Easy to installation
  • Earth grounded

Product Overview

E-PSM (P) Non-invasive Blood Pressure (NIBP) Pump is used in the pneumatics of the patient side module. The patient side module and accessories are used for monitoring hemodynamic parameters for patients. The air pump is used for pumping the measuring pressure of the cuff and the intake air filter for preventing dust and other parts from entering the air pump and the valves. The pump is properly grounded to prevent earth leakage, a rubber pin of a pump bottom cover is inserted into a sinking of a ground contact. Connect an external mercury manometer with a pump to the module through the both tubes of the hose. The pump allows up to 200 mmHg pressure (range of 150 to 300 mmHg allowed) according to the manometer. Verify that both pressure values in the prompt field match the manometer reading, if not adjust by turning the ComWheel. The module automatically pumps a pressure of 260 mmHg in the cuff. Wait for several seconds until the pressure stabilizes, then check that the pressure reading does not drop more than 6 mmHg per minute. The hemodynamic parameters comprise NIBP, temperature, impedance respiration and arrhythmia. NIBP is an indirect method for measuring blood pressure. E-PSM(P) module are necessary parts to measure NIBP measurement.

Compatible Products

S/5 Anesthesia Monitor

S/5 Anesthesia Monitor

S/5 Compact Anesthesia Monitor

S/5 Compact Anesthesia Monitor

S/5 Compact Critical Care Monitor

S/5 Compact Critical Care Monitor

S/5 Critical Care Monitor

S/5 Critical Care Monitor

E Series Parameter Modules

E Series Parameter Modules

S/5 FM

S/5 FM

iCentral WU_1100

iCentral WU_1100

S/5 FM Light Monitor

S/5 FM Light Monitor

Substitute Parts :

Below is more information on the equivalent parts. Parts without a hyperlink are listed for reference only and are not available for purchase online.

Equivalent partPart Details
M1011858
  • Pump Unit E-PSM Manufacturing Assembly
©2024 GE HealthCare
GE is a trademark of General Electric Company. Used under trademark license.