2189553
2154256 45433448
X-Ray
GE HealthCare
Outright
Add to Wish List
Login To Shop
Login To Shop
Please select date
Second Opinion Approval Needed

Enter your approval number and submit to add item(s) to cart.

Approval Number

Please enter approval number

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.

Second Opinion Approval Needed

Select your approver's name and submit to add item(s) to your cart

Approver Name

Please Select Approver Name

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.


Features

  • Critical to Quality (CTQ) characteristics which have customer impact like diagnostic accuracy and patient comfort are provided
  • Designed according to regulations like IEC601-1 International Electro technical Commission, Code of Federal Regulations, HEW Performance Standards for Ionizing Radiation Emitting Products 21 CFR and UL 2601 or UL 187 UL Safety Standards
  • Meets all the performance requirements when oscillating the grid horizontally, vertically and all orientations in between
  • Compatible for usage in the radiographic tables and radiographic wall stands

Product Overview

The MB 2000 Left Hand Medys comes as a part of a radiographic system used for imaging method diagnosis using X-Rays. It is a left hand loading reciprocating Bucky. A stream of electrons produced by X-Ray tube is accelerated to high velocities by an external high-voltage supply and collide with the target anode in the tube. The beam formed is focused on the patient, and X-Rays emerging from the patient carry the image information which can be stored on a film. The Bucky oscillates the grid during radiographic exposures to eliminate visible grid lines in radiographs. It also provides support for the ion chamber, cassette tray, and grid. It is designed for left hand loading, but is also available for right hand loading to allow the cassette tray loading from either side of the Bucky. It also consists of a single design that allows the Bucky to be configured for each side loading configuration or it consists of 2 distinct Bucky designs to achieve both loading configurations. If one design is utilized, the maximum amount of time to configure the Bucky loading shall not exceed 15 minutes.

Compatible Products

Precision 500D

Precision 500D

Robust, digital performance at an efficient dose
It starts with the imaging chain, which features a 12-bit CCD-based camera.Then there’s AutoEx, which automatically adjusts key image-acquisition parameters in real time for optimum quality. Meanwhile, closed-loop Automatic Brightness Control and patented extended Dynamic Range circuitry maintain contrast and minimize blooming.

Equivalent Item(s):

Below is more information on the equivalent item(s). Items without a hyperlink are listed for reference only and are not available for purchase online.

Equivalent Item(s)Item Details
2154256 LIEBEL BUCKY LEFT SIDE LOAD
45433448 BUCKY LIEBEL 248051D